Wiring the incremental encoder connections – Rockwell Automation 2098 Kinetix 6000 or Ultra3000 to Gettys XP Incremental Encoder User Manual
Page 2
Publication 2090-IN015A-EN-P - January 2007
Copyright © 2007 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Wiring the Incremental Encoder Connections
Allen-Bradley, Kinetix, Rockwell Automation, and Ultra3000 are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are the property of their respective companies.
Kinetix 6000 Drive
Gettys Encoder
Ultra3000 Drive
Signal
MF-Pin #
Wire Color
Signal
Notes
Signal
CN2-Pin #
A+
1 White/Green
A+ — A+
1
A- 2 Green/White
A-
A- 2
B+ 3 White/Blue
B+
B+ 3
B- 4 Blue/White
B-
B- 4
Index+ 5
Wht/Orange
Z+
Index+ 5
ECOM 6
Blue/Red Com
ECOM 6
S3 8 Red/Orange
W
S3 8
Index-
10 Orange/White
Z-
Index-
10
S1 12 White/Gray
U
S1 12
S2 13 White/Brown
V
S2 13
EPWR_5V 14
Red/Blue
+Vdc
EPWR_5V 14
Overtemp
(1)
(1)
The Kinetix 6000 and Ultra3000 drives require the use of a Motor Feedback Connector (catalog number 2090-K6CK-D15MF)
with thermal-switch filter terminals to provide Over Temp signal termination. Refer to Wiring the Power Connections on
page 1.
16 Blue Over
Temp
From
Motor
Power cable
TS+
11
17 Blue Over
Temp
6
— Connector
Shield
Drain
Wire/Shield
— — —
Connector
Shield