Rockwell Automation 2094-SEPM-FUSE Kinetix 6000M Integrated Drive-Motor Power Interface Module Fuse Replacement User Manual
Kinetix 6000m fuse replacement kit, Installation instructions, About the fuse replacement kit
Installation Instructions
Kinetix 6000M Fuse Replacement Kit
Catalog Number 2094-SEPM-FUSE
About the Fuse Replacement Kit
The Kinetix® 6000M Integrated Drive-Motor (IDM) system has a pair of internal fuses for
short-circuit protection of the DC bus in the IDM Power Interface Module (IPIM).
The fuse replacement kit contains six Bussmann FWP-50A14Fa fuses.
IPIM Fuse Location
Replacing the IPIM Fuses
Follow these steps to replace the fuse pair in an IPIM module.
1. Remove all control and input power supplied to the Kinetix 6000M system.
2. Wait the full time interval specified in the warning on the front panel of the IPIM
module before proceeding with the next step.
IMPORTANT
Replace both fuses in the fuse holder at the same time. The power surge that opens one fuse
may have stressed and weakened the second fuse.
ATTENTION: Capacitors on the DC bus retain hazardous voltages after input power has been
removed. Before working on the IDM system, measure the DC bus voltage to verify it has reached a
safe level or wait the full time interval as indicated in the warning on the front panel of the IPIM
module.
Failure to observe this precaution could result in severe bodily injury or loss of life.
Phillips Screw (2x)
0.5…0.7 N•m
4…6 lb•in
Reverse View of
Fuse Holder
Mounting Screw
2.26 N•m
20 lb•in