200 Watt Passive Shunt Module
(Catalog Number 9101-1183)
Drives can require external power dissipation when large inertial 
loads are present. To ensure that faults due to excessive bus voltage 
do not occur, loads requiring power dissipation that exceed the 
internal shunt capability require the use of external shunt resistor. 
The passive shunt (Catalog No. 9101-1183, formerly 9101-1079) can be 
used with the following products:
As a motor decelerates, power is returned from the motor to the drive, 
causing the bus voltage to increase. Ultra servo amplifier products 
have circuitry that senses the voltage on the DC bus and dissipates 
power when needed. When the bus voltage reaches the shunt turn-on 
voltage, the internal shunt circuitry allows the excessive regenerated 
power to be dissipated through an external resistor. After the bus 
voltage is reduced to the turn-off voltage level, the shunt transistor 
turns-off and no additional power is dissipated by the shunt resistor. 
Drive
Catalog No.
ULTRA 200™ Drives
1398-DDM-010, -010X, -020, -020X, -030, -030x,-075, and 
-075X 
ULTRA Plus™ Drives
1398-PDM-010, -020, -030, and -075
Ultra3000™ Drives
2098-DSD-030, -030-SE, -030-DN, -030X, -030X-DN, -075, 
-075DN, -075X, and -075X-DN 
Ultra5000™ Drives
2098-IPD-030, -030-DN, -075, and -075-DN
ATTENTION
!
Using the passive shunt with modules not listed can 
cause equipment damage or personal injury. 
Document Outline
- 2090-IN003A-EN-P November 2002
- Front Cover
 - Catalog Numbers
 - Applicable Products
 - Installing the Shunt
 - Product Specifications
 - Module Dimensions
 - Related Documentation
 - Back Cover
 
 - Web Links
- Allen-Bradley Technical Support
 - Industrial Motion Control
 - On-Line Documentation
 - Rockwell Automation
 
 