Rockwell Automation 2364F DC Link Fuse Upgrade Kit for RGU Parallel w/ NRU User Manual
Rockwell Automation Equipment
![background image](/manuals/580438/1/background.png)
Upgrade Kit Instructions
DC Link Fuse Upgrade Kit for RGU in Parallel
with NRU
Contents
This document shows how to install the DC Link Fuse Upgrade Kit for a
Regenerative DC Bus Supply (RGU) in parallel with a Non-Regenerative
DC Bus Supply (NRU).
What This Kit Contains
There are three styles of kits. The contents of the kit vary to accommodate
the size of RGU. Refer to the proper table for your RGU to determine
whether you have all the proper parts.
D-Frame Parts
Table A DC Link Fuse Upgrade Kit for D/K Size RGU // NRU (302102)
E-Frame Parts
Table B DC Link Fuse Upgrade Kit for E/L Size RGU // NRU (302103)
Description
Mequon P/N
Manufacture P/N
Quantity
Fuse
178004
170M3766
3
Microswitch
178219
170H0069
2
Relay
300635
700-CF220D
1
Suppressor
300362
100-FSV136
1
Red Wire
103859
30614
Approximately 200ft
White Wire
103857
30614
Approximately 50ft
Wire Markers
N/A
N/A
N/A
Fuse Tags
N/A
N/A
N/A
Relay Panel Marker
N/A
N/A
1
Description
Mequon P/N
Manufacture P/N
Quantity
Fuse
304377
170M5660
3
Microswitch
178219
170H0069
2
Relay
300635
700-CF220D
1
Suppressor
300362
100-FSV136
1
Red Wire
103859
30614
Approximately 200ft
White Wire
103857
30614
Approximately 50ft
Wire Markers
N/A
N/A
N/A
Fuse Tags
N/A
N/A
N/A
Relay Panel Marker
N/A
N/A
1