Publication 2094-IN006B-EN-P — June 2008

PN 313892-P02

Supersedes Publication 2094-IN006A-EN-P — April 2002

Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

Allen-Bradley, CompactLogix, ControlLogix, Kinetix, Rockwell Automation, SoftLogix, and TechConnect are trademarks of
Rockwell Automation, Inc.

Trademarks not belonging to Rockwell Automation are property of their respective companies.

5. Gently push the module against the power rail connectors and into the final

mounting position.

6. Use 2.26 N•m (20 lb•in) torque to tighten the mounting screw.

7. Repeat steps 1…6 to install a slot-filler module in each empty slot on the

power rail.

Power Rail

Bracket secured

in slot.

IAM, AM, Shunt, or

Slot-filler Module

(IAM module is shown)

Mounting Screw

Bottom front view of

slot-filler module.