Installation Instructions

Kinetix 6000M Hybrid Terminator

Catalog Number 2090-CTHP8

About the Hybrid Terminator

A Kinetix

® 6000M integrated drive-motor system shares DC bus and control power, system

status, and safety signals through a daisy-chain of hybrid cables between each integrated
drive-motor (IDM) in the drive system.

The 2090-CTHP8 hybrid terminator is a male M23 connector with a backshell cover that seals
the connector. The hybrid terminator is installed on the final IDM unit, as shown in the Kinetix
6000M Cable Routing Diagram d
iagram on

page 4

. It terminates the communication bus and

returns the IDM system status signal to the IDM power interface module (IPIM).

2090-CTHP8 Hybrid Terminator

Topic Page

Important User Information

2

Before You Begin

3

Installing the Hybrid Terminator

4

2090-CTHP8 Terminator Schematic and Pinout

5

Specifications 6

Additional Resources

6