Battery Specifications
The 2090-DA-BAT2 battery is required for absolute position backup of TL-Series encoders, but
is not included with the connector kit.
Battery Catalog Number
Battery Life
Cat. No.
Description
2090-DA-BAT2
3.6V, half-height, non-rechargeable lithium battery with 2-pole mini connector
Drive Power On Time
Hours/week
Drive Power Off Time
Hours/week
Expected Battery Life
Years
Operating Conditions
0
168
1.0
Drive power is never ON
40
128
3.5
Drive power is ON for one 8-hour shift,
5 days/week
56
112
4.0
Drive power is ON for one 8-hour shift,
7 days/week
80
88
5.5
Drive power is ON for two 8-hour shifts,
5 days/week
112
56
7.5
Drive power is ON for two 8-hour shifts,
7 days/week
120
48
8.0
Drive power is ON for three 8-hour shifts,
5 days/week
168
0
10.5
Drive power is never OFF
This product contains a sealed lithium battery which may need to be replaced during the life of the product.
At the end of its life, the battery contained in this product should be collected separately from any unsorted
municipal waste.
The collection and recycling of batteries helps protect the environment and contributes to the conservation of