Install the Low-profile Connector Kit
2090-K2CK-D15M Connector Kit Specifications
Attribute
Value
Cable diameter
4…10 mm (0.16…0.39 in.)
Screw terminal wire size
0.06…1.31 mm
2
(30…16 AWG)
Recommended wire strip length
5 mm (0.2 in.) single conductor
Recommended torque
Mounting screw
Terminal screw
0.40 N•m (3.5 lb•in)
0.25 N•m (2.2 lb•in)
ATTENTION: This connector kit contains electrostatic discharge (ESD) sensitive parts that can be
damaged if you do not follow ESD control procedures. If you are unfamiliar with ESD control
procedures, refer to Guarding Against Electrostatic Damage, publication
, or any other
applicable ESD protection handbook.
If necessary, turn clamp over to hold small wires secure.
Mounting
Screw (2)
Tie wrap secures
wire bundles.
Shrink-wrapped
Insulation
Follow these steps to form a compact
connection.
1. Push the insulation down-and-over itself.
2. Move the insulation so it butts against the
outside wall of the cover.
3. Tape or shrink-wrap the end of the
insulation to the cable.
Battery (optional)
Cable Shield Termination Pad
Cable Shield