NRU/RGU DC Bus Energized Pilot Light and Legend Plate Replacement

3

Step 3: Installing the New
Pilot Light and Legend Plate

1. Place the proper combination of gaskets, determined from Table 1 below,

onto the bushing and insert the bushing through the rear of the panel. The
surface marked “TOP” should be in line with the anti-turn notch in the
panel.

Figure 1 Bulletin 800MR Pilot Light Assembly

2. Install the legend plate on the bushing in line with the anti-turn notch in

the panel.

3. Thread the “thin” mounting ring onto the bushing and tighten to

compress the gaskets and to secure the unit on the panel.

4. Push the lens assembly into the bushing.

5. Thread the “tall” mounting ring onto the bushing and tighten against the

thin mounting ring.

Table 1: Number of Gaskets Required
Panel Thickness

.067 in. (1.7 mm) Gasket (Black) +

.034 in. (0.9 mm) Gasket (Red)

1/16 in. (1.6 mm)

3

+

2

3/32 in. (2.4 mm)

3

+

1

1/8 in. (3.2 mm)

3

+

0

5/32 in. (4.0 mm)

2

+

1

3/16 in. (4.8 mm)

2

+

0

7/32 in. (5.6 mm)

1

+

1

1/4 in. (6.4 mm)

1

+

0