Locating mounting bracket features, Mounting and orientation, Figure 2 mounting bracket features – Rockwell Automation 2094 2094 Mounting Bracket Installation Instructions User Manual
Page 3: Figure 3 mounting brackets with power rail

2094 Mounting Brackets 3
Publication 2094-IN008B-EN-P — November 2004
Locating Mounting Bracket Features
Figure 2
Mounting Bracket Features
Mounting and Orientation
When using mounting brackets to mount the power rail, orient the
brackets and AC line filter as shown in Figure 3.
Figure 3
Mounting Brackets with Power Rail
1
For more information on bonding subpanels, refer to the System Design for Control of Electrical Noise Reference
Manual (publication GMC-RM001x-EN-P).
Note: For 2094 power rail dimensions, refer to the Kinetix 6000 Installation Manual (publication 2094-IN001x-EN-P).
LIM
PRS
PR
LIM
PR/PRS
For use when mounting 2094-PRSx Power Rail
(except -PRS1 bracket in right most position)
Mounting Bracket
(2094-XNBRKT-1)
For use when mounting LIM
For use when mounting
Power Rail (2094-PRSx or PRx)
For use when mounting
Power Rail (2094-PRx)
For use when mounting 2094-PRS1 Power Rail
(bracket in right most position)
Ground Stud
For use when mounting LIM
LIM
PRS
PR
LIM
PR/PRS
LIM
PRS
PR
LIM
PR/PRS
LIM
PRS
PR
LIM
PR/PRS
Mounting Bracket (2094-XNBRKT-1)
AC Line Filter
(2090-XXLF-3100 shown)
IMPORTANT: The braided ground strap must
be removed from the power rail and attached to
a mounting bracket ground stud.
Bonded cabinet ground
1
To ground grid or power
distribution ground.
Braided ground strap
100 mm (3.9 in.)
Ground Stud