Servo card to termination panel connection, Installing the card – Rockwell Automation 1784-PM02AE PCI 2 Axis Servo Card User Manual
Page 8
8 PCI 2 Axis Servo Card
Publication 1784-IN005B-EN-P- July 2002
It is a slotted rotary switch with 16 switch positions – 0 through 9
and A through F. The switch is accessible by a flathead screwdriver
through the PCI slot at the rear of the computer.
LED
There is one bi-color LED to indicate the status of the Servo card. It
is visible through the PCI slot at the rear of the computer.
At start up the LED goes through a sequence of color changes:
•
At power up LED is Green.
•
When SoftLogix driver starts the LED turns Red.
•
At download of a valid program the LED is Green.
During regular operation the LED is GREEN when the Servo card is
functioning normally and RED when a fault situation occurs.
Servo Card to Termination Panel Connection
The connection on the back of the Servo card accepts a straight 68
way Mini D shielded plug with a spring latch.
Installing the Card
Before you install the card, be certain you know how to:
•
Install hardware in your computer.
•
Configure the computer’s options such as: disable cache
memory, memory manager, and shadowing of memory, before
you install the card.
•
Enable bus mastering and DMA.
Consult your computer’s documentation for specific information.
To install the card, you need:
•
Access to the computer’s expansion slots.
•
Have either a Phillip-head or a flat-head screwdriver.
•
Administration rights to NT.