Indicator Status for Modules
Status
Description
Module status
Off
No power applied to device.
Green
Device operating normally.
Flashing green
Device needs commissioning due to missing, incomplete, or
incorrect configuration.
Flashing red
Recoverable fault.
Red
Unrecoverable fault – may require device replacement.
Flashing red/green Device is in self-test mode.
Network status Off
Device is not online:
- Device has not completed dup_MAC-id test.
- Device not powered – check module status indicator.
Flashing green
Device is online but has no connections in the established state.
Green
Device is online and has connections in the established state.
Flashing red
One or more I/O connections are in timed-out state.
Red
Critical link failure – failed communication device. Device detected
error that prevents it from communicating on the network.
Flashing red/green Communication faulted device – the device has detected a network
access error and is in communication faulted state. Device has
received and accepted an Identity Communication Faulted Request
– long protocol message.
Run status
Off
Module is commanded to stop retrieving SSI data.
Green
Module is commanded to retrieve SSI data.
Up status
Off
SSI data not increasing, or no SSI data is being received.
Green
SSI data is increasing.
Down status
Off
SSI data not decreasing, or no SSI data is being received.
Green
SSI data is decreasing.
Comp status
Off
Comparator function is not in use, or comparator value not attained.
Green
Comparator value attained.
I1 status
Off
Latching input I1 is OFF.
Green
Latching input I1 is ON.