beautypg.com

Connections, Lamp run time indication while running, Lamp light output indication – Barco R9010010 User Manual

Page 32: Lamp z-axis indication

background image

4. Connections

Lamp run time indication while running

When the total run time of the lamp is 30 hours less then 1000 , the following warning message will be displayed for 1 minute. This
warning message will be repeated every 30 minutes. Press EXIT to remove the message before the minute is over.

Remaining
Lamp run time
20h

Image 4-2

When the total run time of the lamp is 1000 hours or more, the following warning message, with the exact run time is displayed on
the screen.

WARNING

Lamp run time is x hours

operating the lamp longer

than x hours may damage

the projector.

Please replace the lamp

to continue

Menu 4-1

Lamp run time is 1000 hours. Operating the lamp longer than maximum runtime hours may damage the projector. Please replace
the lamp.

When ENTER is pressed to go on, the warning will be repeated every 30 min.

The total lifetime of the lamp for a safe operation is 1000 hours max. Do not use it longer. Always replace with a same type of lamp.
Call a BARCO authorized service technician for lamp replacement.

C

AUTION

:

Using a lamp for more than 1000 hours is dangerous as the lamp could explode.

Lamp Light Output Indication

When starting up and the center lumens measurement is lower than 50 % of its initial value, the lamp light output warning will be
displayed. Press ENTER to continue. The message will not be repeated during operation.

WARNING

Lamp run time is X hours

The light output of the lamp

is less

than 50% of its initial value.
It is advisable to replace the

lamp

before damage occurs.

to confirm

Menu 4-2

When the ’Constant Light Output’ (CLO) options is installed, the light output message will appear on the screen when the light output
is reduced with 33% from its initial value.

This message will be repeated every hour.

Lamp Z-axis indication

When starting up and the run time is 100 hours or 250 hours a Z-axis warning will be displayed. This warning will advise to adjust the
Z-axis of the lamp to obtain maximum light output. Press ENTER to continue. The message will not be repeated during operation.

WARNING

Lamp run time is X hours.

It is advisable to

adjust the Z-axis

of the lamp to
obtain maximum

light output

(see owner’s manual)

to confirm

Menu 4-3

28

R5976563 BARCOR10 SLM 20/10/2004