Install or Replace the Battery
To install or replace the 1770-XYV battery, follow these steps.
1. If you are installing a replacement battery, pull the battery-cover
pins out to unlock the cover, and remove the cover.
2. Remove the depleted battery.
3. Insert the new or replacement battery according to polarity.
4. Place the cover over the installed battery, and push the pins in
to lock.
5. Write the installation date on the battery cover.
Average 1770-XYV Battery Lifetime
The 1770-XYV battery contains 0.15 grams of lithium. Refer to the
following table for details regarding the average lifetime of this
battery.
This product contains a sealed lithium battery that may need to be
replaced during the life of the product.
At the end of its life, the battery contained in this product should be
collected separately from any unsorted municipal waste.
The collection and recycling of batteries helps protect the environment and
contributes to the conservation of natural resources as valuable materials
are recovered.
At this temperature
Lifetime with
Battery Power Off 100%
Lifetime with
Battery Power Off 50%
60 °C (140 °F)
40 days
125 days
25 °C (77 °F)
6 months
8 months