14 Compact™ 16-Point 100 to 240V ac Solid State Output Module

Publication 1769-IN061A-EN-P - December 2001

Specifications

General Specifications

Specification

Value

Dimensions

118 mm (height) x 87 mm (depth) x 52.5 mm (width)
height including mounting tabs is 138 mm
4.65 in. (height) x 3.43 in (depth) x 2.07 in (width)
height including mounting tabs is 5.43 in.

Approximate Shipping Weight
(with carton)

410g (0.90 lbs.)

Storage Temperature

-40°C to +85°C (-40°F to +185°F)

Operating Temperature

0°C to +60°C (32°F to +140°F)

Operating Humidity

5% to 95% non-condensing

Operating Altitude

2000 meters (6561 feet)

Vibration

Operating: 10 to 500 Hz, 5G, 0.030 inches maximum
peak-to-peak
Relay Operation: 2.0G

Shock

Operating: 30G panel mounted (20G DIN rail mounted)
Relay Operation: 7.5G panel mounted (5G DIN rail mounted)
Non-Operating: 40G panel mounted 30G DIN rail mounted)

Agency Certification

C-UL certified (under CSA C22.2 No. 142)

UL 508 listed

CE and C-Tick compliant for all applicable directives

Hazardous Environment Class

Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL
1604, C-UL under CSA C22.2 No. 213)

Radiated and Conducted Emissions

EN50081-2 Class A

Electrical /EMC:

The module has passed testing at the following levels:

ESD Immunity (IEC61000-4-2)

4kV contact, 8 kV air, 4 kV indirect

Radiated Immunity (IEC61000-4-3)

10 V/m, 80 to 1000 MHz, 80% amplitude modulation,
+900 MHz keyed carrier

Fast Transient Burst (IEC61000-4-4)

2 kV, 5 kHz

Surge Immunity (IEC61000-4-5)

2 kV common mode, 1 kV differential mode

Conducted Immunity (IEC61000-4-6)

10V, 0.15 to 80 MHz

(1)

(1)

Conducted Immunity frequency range may be 150 kHz to 30 MHz if the Radiated Immunity frequency range is 30 MHz to
1000 MHz.