Replacement bearings, Table e, Table c – Rockwell Automation 1329R Std. Industrial AC Induction Motors User Manual
Page 17: Table d

Standard Industrial AC Induction Motors
17
Table C
Service Conditions
Table D
Lubrication Frequency for Ball Bearings
Lubrication Frequency for Roller Bearings
For Roller Bearings – divide the above times by 2.
Table E
Recommended Volume
Replacement Bearings
Your maintenance program will not be complete without including
spare bearings. It must be remembered that the bearing is a wearable
component and therefore must eventually be replaced. To ensure that
you are able to maintain original operation, we recommend the
purchase of spare parts directly from Allen-Bradley.
All bearings are subject to exact specifications and tests necessary to
satisfy performance requirements. In this manner, it is possible to
duplicate your present bearing. Markings on the bearing do not
indicate complete specifications.
!
ATTENTION: Mixing lubricants is not recommended due
to possible incompatibility. If changing lubricant without
motor disassembly is desired, follow lubrication
instructions and repeat lubrication after 100 hours of
service. Care must be taken to look for signs of lubricant
incompatibility, such as extreme “soupiness” visible from
the grease relief area. Failure to observe this precaution
could result in damage to or destruction of the equipment.
Standard Conditions:
Eight hours per day; normal or light loading, clean, 40 degree C
(100 degrees F) maximum ambient.
Severe Conditions:
Twenty-four hour per day operation or shock loading, vibration, or in
dirt or dust at 40-50 degrees C (100-120 degrees F) ambient.
Extreme Conditions:
Heavy shock or vibration, or dust.
Speed
NEMA (IEC) Frame
Condition
Standard
Severe
Extreme
1800 RPM & slower
182- 215 (112-132)
3 Years
1 Year
6 Months
254-365 (160-200)
2 Years
6-12 Months 3 Months
404-449 (225-280)
1 Year
6 Months
1-3 Months
3600 RPM
All
6 Months
3 Months
1 Month
NEMA (IEC) Frame
Volume in Cubic Inches (cm
3
)
182- 215 (112-132)
0.5 (8)
254-286 (160-180)
1.0 (16)
324-365 (200-225)
1.5 (24)
404-449 (250-280)
2.5 (40)