Wiring specifications – Rockwell Automation 1397 Pulse Encoder Interface Installation Inst. User Manual
Page 8
1397 Pulse Encoder Interface Card
8
1397-5.13 June, 1997
Shield
1
to Chassis
Ground Stud
71 +15V
72 COM
73 A
74 A
Single Channel
Pulse Encoder
— No Motor Reversing —
75 B
76 B
TB J6
TB J5
A
(High)
(Low)
(High)
(Low)
A
Period
2
1
Belden 9728 or 9730 — (2) Conductor Twisted Shielded Cable
Refer to the Cable and Wire Recommendations in the 1397 Use
Manual for additional Wiring Specifications
2
Period = 1
frequency
Non-Regenerative Drives — Non-Reversing Motor Applications
Shield
1
to Chassis
Ground Stud
71 +15V
72 COM
73 A
74 A
Quadrature
(Dual-Channel)
Pulse Encoder
for
Regenerative Drives
75 B
76 B
TB J6
TB J5
B
A
(High)
(High)
(High)
(Low)
(Low)
(Low)
(High)
(Low)
A
B
Period
2
1
Belden 9728 or 9730 — (2) conductor twisted shielded cable.
Refer to the Cable and Wire Recommendations in the 1397
User Manual for additional wiring specifications.
2
Period = 1
frequency
Regenerative Drives — Reversing and Non-Regenerative Motor Applications
Wiring Specifications
Terminal Blocks J5 and J6 are available for either regenerative or
non-regenerative drive connection.
Note: Only regenerative drives allow motor reversing. Regenerative
drives require that quadrature pulse encoders be used.
ATTENTION: The incorrect wiring of the pulse encoder
and/or motor can cause an overspeed condition. Verify
correct motor and pulse encoder polarity in the Start-Up and
Adjustment section of the 1397 User Manual. Failure to
observe this precaution could result in bodily injury.
!