Display the Spectrogram Plot

When you are done setting up the plot parameters, you can process the spectral
data by pressing F3 (Display) on the RUCD - Spectrogram Setup screen.

Optimize the Spectrogram Plot

Additional parameters display on the screen letting you to control how the
spectra appear in the spectrogram plot.

1.

Select a parameter and press the Right arrow to open a list of values.

2.

Select or type in a parameter value.

3.

Press the Left arrow to save your selection.

Use the descriptions in

Spectrogram Plot Setup Parameters on page 39

to

help you configure the parameters.

4.

When you are finished and ready to display data, press F3 (Display) to view
the Spectrogram.

Freq. Range (EU)

The maximum frequency for the measurement.

The frequency range is determined by the X-axis parameter.

10…2000 Hz

600…120000 CPM

.001…166 Orders

LF Cutoff (EU)

Sets a low frequency cutoff filter to remove noise from the analysis.

The available options are determined by your X-axis selection.

Off

21.6 CPM

66 CPM

120 CPM

600 CPM

4200 CPM

.36 Hz

1.1 Hz

2 Hz

10 Hz

70 Hz

Table 9 - Spectrogram Plot Parameter Descriptions

Parameter Name

Description

Values/Comments

TIP

The larger the .wav file, the longer it takes to process the data
and display the plot.