For more information refer to our web site – Rockwell Automation 1394 Shunt Modules Fuse Replacement Kit User Manual
Page 4
![background image](/manuals/578506/4/background.png)
Publication 1394-6.6 March 1999
193591
1999 Rockwell International. All Rights Reserved. Printed in USA
7.
Remove the fuse from the fuse holder with the fuse puller tool.
8.
Close the door panel.
9.
Secure the door panel.
10. Attach the new fuse label over the existing fuse label on the front door panel
of the shunt module.
Figure 5
New Fuse Label Attached to the 1394 Shunt Modules
11. Apply power to your system including the shunt module.
For more information refer to our web site:
www.ab.com/motion
If your 1394-SR9A, -
SR9AF, -SR36A, or -
SR36AF shunt
module:
Replace the fuse with a:
Has the UL mark
Bussmann 600V DC 50A fuse
(FWP50A14F) or equivalent.
Does not have the UL
mark
Bussmann 600V DC 40A fuse
(170N2013) or equivalent.
1394-SR36A/36AF
1394 Digital Servo Controller
3600W Shunt Module
1394-SR9A/9AF
1394 Digital Servo Controller
300W Shunt Module
BULLETIN 1394 3600W SHUNT MODULE
ALLEN-BRADLEY
FOR USE WITH 1394-SJT22-X SYSTEM MODULE
CAT.
PART
SER.
INPUT DC
INPUT AC
BULLETIN 1394 300W SHUNT MODULE
ALLEN-BRADLEY
FOR USE WITH 1394-SJT22-X SYSTEM MODULE
CAT.
PART
SER.
INPUT DC
INPUT AC
Fuse Label
Fuse Label
FOR FUSE REPLACEMENT USE:
BUSSMAN CAT. NO.
FOR FUSE REPLACEMENT USE:
BUSSMAN CAT. NO.
R
R
For more information refer to our web site: www.ab.com/motion
For Rockwell Automation Technical Support information refer to: www.rockwellautomation.com/support or Tel: (1) 440.646.3434