Power Supply
The external voltage supply (+24V DC) must meet the requirements of
IEC 61496-1. In addition, the following requirements have to be
fulfilled:
• A short-term power failure of 20 ms must be bridged by the power
supply.
• The power supply has double insulation between the primary and
the secondary side.
• The power supply is protected against overload.
• The power supply corresponds to the guidelines of the EWG
(industrial environment).
• The power supply corresponds to the Low Voltage Directives.
• The grounded conductor of the power supply device must be
connected to a grounded conductor PE.
• The maximum deviation of the voltage levels is 24V DC +/- 20%.
EDM Connection
Figure 9: Connecting the contact elements to the EDM
Start/Restart interlock
Note: Start/restart interlock requires a N.O. momentary push button or
key switch.
Figure 10: Connecting the reset button/restart button
Connections [mm (in.)]
Cables/Connectors
The GuardShield Type 2 transmitter connector is a four-pin DC micro
connector offered in cable lengths from 2 to 30 meters. The GuardShield
Type 2 receiver connector is an 8-pin DC micro connector offered in
cable lengths of 2 to 30 meters.
Standard GuardShield Type 2 Receiver Connector
Double insulation
This part of the insulation provides
supplementary insulation against
hazardous voltage levels.
Motor, etc.
Hazardous voltage level
Basic insulation
Hazardous
Hazardous
Reinforced
insulation or
double
Unit 1
Power
Supply Unit
Output (pink
Basic insulation
Basic insulation
0V (blue)
+24V (brown)
K1
K1
K2
K2
GuardS
hield
24V
Pin 4
5
6
K1
K2
k2
k1
Contactor
Contacts
Contactor
Coils
Transmitter Connection
Face View of
Female DC Micro
Color
Pin No.
Signal
Transmitter
Brown
1
+24V DC
White
2
No Connection
Blue
3
0V DC
Black
4
Machine Test Signal
Receiver Connection
Face View of
Female DC Micro
Color
Pin No.
Signal
Receiver
White
1
Auxiliary Output
Brown
2
+24V DC
Green
3
Ground
Yellow
4
EDM
Grey
5
OSSD 1
Pink
6
OSSD 2
Blue
7
0V DC
Red
8
Start/Restart
Pin 8
Reset/restart button
24V
1
4
3
2
2
1
5
8
7
6
4