3.2.6 Prick each of the copper wires with one of

the needles. Press the needle contacts of
the connector in the direction shown:
(wedge outwards), straight into the copper
wires.

3.2.7 CAUTION

The narrow side (wedge) of the connector
must show outwards.

3.2.8 Fold back the sealing lip of the cap;

a) Apply adhesive to shaded area of closing

cap as illustrated then affix to edge of
profile, applying pressure for 10 seconds
to ensure adhesion.

b) Apply adhesive to remainder of shaded area

and allow sealing lip to make contact with profile.

IMPORTANT: Spread the adhesive evenly over the
shaded area! Do not allow adhesive to enter inside
the profile.

5.3 APPLICATIONS

Z1

Z2

+

-

Brown

White

L

6K

RESISTOR

STOP

START

110/230V AC SUPPLY

110/230V AC Application with 2 contactors, contactor monitoring
and START/STOP circuit. (Shown with profile pressed)

MOMENTARY
PUSH BUTTON

EXTERNAL FUSE

+ve Z1 Z2 13 23 31

N

E -ve MC MC 14 24 32

SAFEDGE

PROFILE

SAFEDGE

CONTROL UNIT

K1

K1

K2

K2

K1

K2

(A1)

(A2)

L

6K

RESISTOR

K1

EXTERNAL FUSE

110/230V AC Application with 1 contactor.
(Shown with profile pressed).

+ve Z1 Z2 13 23 31

N

E -ve MC MC 14 24 32

SAFEDGE

PROFILE

SAFEDGE

CONTROL UNIT

(A2)

(A1)