beautypg.com

Smc-3, E - doc, Set motor fla – Rockwell Automation 150-CSxxx SMC-3 Soft Starter (3 Phase Installations) User Manual

Page 2: Revision authorization

background image

Sequence

Dip

Switch

Number

Settings

Current Limit

Soft Start

Settings

Current Limit Start

Current Limit

I

S

Up to

Speed

Normal

t

2

t

1

U

s

U

e

U

e

Up to

Speed

Normal

t

3

t

2

t

1

U

s

U

e

t

3

Ie

I

S

U

s

U

e

U

s

U

e

t

1

Ie

I

S

t

1

t

2

t

1

I

e

I

s

I

k

1

2

3

4

5

6

7

3

3

Soft Start

(3)

(4, 5)

(9, 10)

(1, 2, 8)

(6, 7)

(14)

(14)

(11,12)

(13)

(16)

150%

250%

350%

450%

4 5

4 5

4 5

4 5

Start Time

2

5

10

15

1 2

1 2

1 2

1 2

8

8

8

8

8

8

8

20

25

1 2

1 2

30

1 2

t

1

(sec)

Start Time

2

5

10

15

1 2

1 2

1 2

1 2

8

8

8

8

8

8

8

20

25

1 2

1 2

30

1 2

t

1

(sec)

Kick Start

I

k

= 450% FLAt

2

(sec)

Off

0.5

1.0

1.5

9 10

9 10

9 10

9 10

Kick Start t

2

(sec)

Off

0.5

1.0

1.5

9 10

9 10

9 10

9 10

Soft Stop

Off

1 x t

1

2 x t

1

3 x t

1

6 7

6 7

6 7

6 7

t

3

(sec)

Soft Stop

Off

1 x t

1

2 x t

1

3 x t

1

6 7

6 7

6 7

6 7

t

3

(sec)

Aux. #1

Normal

Up To

Speed

Normal

Up To

Speed

Optional Aux. #2

14

14

14

14

Overload (OVLD)

Trip

Class

Trip

Class

Trip

Class

Trip

Class

OFF

10

15

20

(2)

11 12

11 12

11 12

11 12

Overload (OVLD) Reset

Manual

Auto

13

13

Phase Rotation

Enabled

Disabled

16

16

(%FLA)

Initial Torque

U

S

15%

25%

35%

65%

4 5

4 5

4 5

4 5

(%LRT)

t

1

Aux. #1

Normal

Up To

Speed

Up To

Speed

Normal

Optional Aux. #2

14

14

14

14

Enabled - No Fault
Disabled- No Fault

1 L1

3 L2

5 L3

A

B

C

Enabled - Fault
Disabled- No Fault

1 L1

3 L2

5 L3

A

B

C

97 - 98

Fault

Push to Reset

A1 - A2

Fault Contact (97, 98)

9

Set Motor FLA

(15)

8

Delta

Line

Line or Delta

15

15

M

3~

2 / T1

4 / T2

6 / T3

10 / T5

8 / T4

12 / T6

M

2 / T1

4 / T2

6 / T3

Line

Delta

2

4

SMC-3

TM

(108-135 A)

INSTALLATION INSTRUCTION SHEET

5

1028330

6

1033871

41053-323

OF

N/A

N/A

N/A

REVISION

AUTHORIZATION

DR.

CHKD.

APPD.

DATE

DATE

DATE

E - DOC

LOCATION: MILWAUKEE, WISCONSIN U.S.A.

B-vertical.ai

DWG.

SIZE

SHEET

B

1

2

3

4

5

6

7

8

A

B

C

D

E

F

G

H

REFERENCE

DIMENSIONS APPLY BEFORE

SURFACE TREATMENT

(DIMENSIONS IN INCHES)

TOLERANCES UNLESS

OTHERWISE SPECIFIED

.XX:

.XXX:

ANGLES:

41053

THIS DRAWING IS THE PROPERTY OF

ROCKWELL INTERNATIONAL CORPORATION

OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,

USED OR DISCLOSED FOR ANY PURPOSE

EXCEPT AS AUTHORIZED IN WRITING BY

ROCKWELL INTERNATIONAL CORPORATION

------------

---------
---------

---------

------------

------------