1) Remove and lockout power sources feeding the unit.
2) Turn unit disconnect switch to the “OFF” position.
3) Remove all of the quick connect cables from the Control Module.
4) Loosen the four mounting screws on the Control Module.
5) Unplug the Control Module from the Base Module by slowly pulling straight forward.
WARNING
To prevent electrical shock, disconnect from power source before installing or servicing.
WARNING
The drive contains high voltage capacitors which take time to discharge after removal of main supply. Before working on drive, ensure
isolation of main supply from line inputs (R, S, T [L1, L2, L3]). Wait three minutes for capacitors to discharge to safe voltage levels. Failure
to do so may result in personal injury or death. Darkened display LEDs are not an indication that capacitors have discharged to safe voltage
levels.
Removal of Control Module
*The removal of the Base Module is only required for Base Module Replacement. If only the Control Module is being replaced, skip to Step 18.
6) Remove communications, input, and output cables from the Base Module.
7) Loosen the four mounting screws on the
Terminal Access Cover Plate.
8) Remove cover plate.
9) Loosen terminal screws.
10) Remove all wires from terminal
block.
11) Remove conduit fittings.
Removal of Base Module
With Conduit / Cable
With ArmorConnect Media
Motor
Cable
Terminal Access
Cover Plate
6
1
3
7
8
9
10
5
4
2
Control
Module
CAUTION
Verify that power is removed to motor, inputs, and outputs before replacing any module.
Control
Module
Base
Module
Disconnect SM
wire connection
between Control and
Base Modules
6) Remove communications, input and output cables from the Base
Module.
7) Remove the ArmorConnect Media from the gland plate by
loosening the fastner and un-plugging.
Skip to Step 12.
12) Loosen unit mounting screws and remove the Base Module.
12
3-Phase
Control
Voltage
-Bulletin 284D shown-
When Safety Monitor option used, there
is a wire connection between the Control
and Base Module that needs to be
disconnected.
Base