CAUTION:

Do not apply reverse energization during trial runs

until it has been determined that the speed switch contacts
in the reverse circuit are re-closing at a safe speed for the
particular application.

SPEED SENSING AND DIRECTION OF ROTATION

T u r n a d j u s t i n g

screw(s) out for lower speed, and in for higher speed sensing of
shaft. Adjust both screws when contacts are wired for sensing
shaft speed in each direction of rotation.

WIRING INSTRUCTIONS

Remove cover with nameplate, ex-

posing contact block. Use wire suitable for at least

C. Check

application notes for recommended wiring diagrams.

NOTE:

Contact blocks are supplied with a common jumper

which may be removed if isolated contacts are desired. Replace
cover, torque cover screws 8-10 in.-lbs.

INTERCHANGEABLE MOUNTING BRACKETS

3 Point Flange

4 Point Flange

MOUNTING

Three types of interchangeable mounting brackets

are available for NEMA Type 1,4 and 13 speed switches. NEMA
Type 7 & 9 switches are available with base type mounting

bracket only. (See Table 3.)

Brackets, except on NEMA Type 7 & 9 switches, can be

mounted to the switch in any of eight positions, one position of

which is used to locate the conduit opening in the most

convenient position for the electrical connection. Bracket X-
268875 used on NEMA Type 7 & 9 switch is mounted in one
position. Mounting brackets are attached with four slotted
screws and lock washers.These screws should be torqued to
20-24 in.-lbs.

TABLE 3

M O U N T I N G B R A C K E T S I

Oescriotion

Catalog Number

Base Mounting (NEMA Type 1, 4 and 13)

3 Point Flange Mounted

4 Point Flange Mounted

808-N1

808-N2
808-N3

Part Number

Base Mounting (NEMA Type 7 & 9)

I

X-268875

I

MAINTENANCE

Periodic inspection of the shaft seal is

suggested. If seal wear is evident, replace with external bearing
seal kit. Catalog Number 808-N5 Installation instructions are
included with replacement kit.

not attempt to disassemble the shaft assembly.

attempt may permanently damage the speed

Bearings are sealed and are of the permanently lubricated

type. In severe environments, such as cement dust, the shaft
seal should be cleaned and lubricated with “Anderol 757” or
equivalent. “Anderol 757” is a synthetic diester multi-purpose
grease.

L o c k o u t
C o v e r

Solenoid Fork

Speed Switch

With Lockout Solenoid

NEMA Type 1, 4

and 13 Enclosure

Exploded View of

Speed Switch with Lockout Solenoid

LOCKOUT SOLENOID

The Bulletin 808 can be equipped with a

lockout solenoid which consists of solenoid and cover
mounted on top of the switch. To add a lockout solenoid,
remove the top plate (4 screws) and mount the solenoid bracket

to the housing with two #10-32 x

screws provided. These

screws should be torqued to 20-24 in.-lbs. The lockout solenoid

fork must straddle the copper operating lever (see exploded
view). Mount cover as shown in exploded view with two #8--32 x

1” screws provided. Be sure the top plate gasket is in place
before torquing cover screws, 8-10 in.-lbs.

TABLE 4

L O C K O U T SOLENOID K I T S

I

120 6 0 4 8 0 6 0

110 5 0 808-NLA1 4 4 0 5 0 808-N LA4

2 0 8 6 0 808-NLA20 600 60

240 6 0

2 2 0 5 0

TYPICAL LOCKOUT SOLENOID CONNECTIONS

(if used)

NOTE:

See applicable standards, codes, and laws for all

applications.

MOTOR

T1

T2

L O

FIGURE 5

3