beautypg.com

Msr245 – Rockwell Automation 440R MSR245 Minotaur Safety System Display User Manual

Page 2

background image

MSR245 Manual 2

MSR245-manual-doc

page 2 of 6

+

_

<_

MSR245

1

2

3

4
5
6
7

Front panel MSR245

1. Key-switch: display-reset
2. Key-switch: forward
3. Key switch: backward
4. Display line1
5. Display line2
6. Display line3
7. Displayline4


Key-switches 2 and 3 are used to select the various display menus. After the System is
switched on, and the MSR245 receives valid data from the MSR240, the Display Module
shows the following information:

Line 1: Automatic re-set (or) Manual re-set
Line 2: Output active (or) Output

deactivated

Line 3: System ready (or) Monitoring

active (or) EDM circuit open

Line 4: Dynamic EDM (or) Static EDM


This is the default menu, to which the MSR245 can be re-set at any time by pressing “

←”

(key-switch 1). Press “+” (key-switch 2) to step to the next menu option, or “-” (key-switch
3) to step to the previous menu option