beautypg.com

Step 2: removing power from the heat exchanger, Step 3: opening the electrical box door – Rockwell Automation 20L-LL PowerFlex 700L Liquid-to-Liquid Heat Exchanger Control Board Replacement User Manual

Page 3

background image

PowerFlex® 700L Liquid-to-Liquid Heat Exchanger Control Board Replacement

3

Step 2: Removing Power
from the Heat Exchanger

A. Turn off and lock out input power.

B. Verify that there is no voltage at the heat exchanger’s input power

terminals.

Step 3: Opening the
Electrical Box Door

Using the flat blade screwdriver, turn the locking mechanism on the
electrical box door counterclockwise one-quarter turn and open the door.

!

ATTENTION: Remove power before making or breaking cable
connections. When you remove or insert a cable connector with
power applied, an electrical arc may occur, which can cause
personal injury or property damage by:

• sending an erroneous signal to your system’s field devices,

causing unintended machine motion

• causing an explosion in a hazardous environment

Electrical arcing causes excessive wear to contacts on both the
module and its mating connector. Worn contacts may create
electrical resistance.

L1

L2

L3

O

I

Electrical Box

Locking
Mechanism