beautypg.com

Rockwell Automation 22A PowerFlex 4 Custom Firmware Instructions - Option DA User Manual

Powerflex 4 custom firmware, Overview, About parameters

background image

Overview

The purpose of this insert instructions manual is to provide the special information
about the custom firmware.

This custom firmware option adds support for the maximal output frequency [Drive Speed]
up to 300 Hz, and quick stop DC braking function.

About Parameters

Compared to the standard firmware, the custom firmware has added the following new
parameters, changed the following standard parameters. During configuration and
parameters programming, it should pay attention.


P032 [Motor NP Hertz]

Values

Default 60

Hz

Min/Max:

10/300

Hz

Display:

1

Hz

P034 [Minimum Freq]

Values

Default 0.0

Hz

Min/Max:

0.0/300.0

Hz

Display:

0.1

Hz

ATTENTION:

The Custom Firmware supplied is designed for a

specific application and load condition. It differs from the standard
PowerFlex4 product offering and must be installed and run only under
this custom application. Attempting to run this Custom Firmware under
any other type of application, could result in unpredictable and/or
hazardous conditions.

ATTENTION:

The drive contains ESD (Electrostatic Discharge)

sensitive parts and assemblies. Static control precautions are required
when installing, testing, servicing, or repairing this assembly.
Component damage may result if ESD control procedures are not
followed. If you are not familiar with static control procedures, reference
A-B publication 8000-4.5.2, “Guarding Against Electrostatic Damage”

PowerFlex 4 Custom Firmware

“ DA” Option – 300 Hz Maximum Frequency and Quick Stop (EBM)

Instructions

Table of contents