Parameter List
Parameter
No. Name and Description
Details
01
[Startup Display]
Selects the display screen shown when the HIM is powered up.
Default:
0 = Main Menu
Values
0 = Main Menu
1 = Process Disp
2 = Large Disp
3 = Startup Param
Type:
Read/Write
02
[Startup Param]
Selects a desired drive parameter to be displayed if Parameter 01 -
[Startup Display] is set to “3” (Startup Param).
Default:
1
Minimum: 1
Maximum: 65535
Type:
Read/Write
03
Reserved
04
[User Disp Line 1]
Selects a desired drive parameter to be displayed on User Display
Line 1 of the Process Display screen.
For example, setting to “3” selects PowerFlex 4-Class drive
Parameter 3 - [Output Current] to be displayed.
Default:
3
Minimum: 1
Maximum: 65535
Type:
Read/Write
05
[User Disp Line 2]
Selects a desired drive parameter to be displayed on User Display
Line 2 of the Process Display screen.
For example, setting to “5” selects PowerFlex 4-Class drive
Parameter 5 - [DC Bus Voltage] to be displayed.
Default:
5
Minimum: 1
Maximum: 65535
Type:
Read/Write
06
[Large Disp Param]
Selects a desired drive parameter to be displayed on the Large
Format User Display screen.
For example, setting to “1” selects PowerFlex 4-Class drive
Parameter 1 - [Output Freq] to be displayed. Setting to “0” enables
the Scaled Reference to be displayed.
Default:
1
Minimum: 0
Maximum: 65535
Type:
Read/Write
07
[LCD Contrast]
Sets the HIM LCD contrast level.
Default:
50%
Minimum: 0%
Maximum: 100%
Type:
Read/Write
08
[Reset HIM]
1 (Reset):
Resets the HIM.
2 (Set Defaults): Resets HIM parameters to factory settings.
This parameter returns to a value of “0” (Ready) after the reset
function is complete.
Default:
0 = Ready
Values
0 = Ready
1 = Reset
2 = Set Defaults
Type:
Read/Write
09
[Device Type]
Selects the HIM device type. When set to “0” (Auto), the HIM is
automatically configured as either a DSI Master or Slave depending
on the presence of other peripheral devices.
Default:
0 = Auto
Values
0 = Auto
1 = Slave
2 = Master
Type:
Read/Write
10
[M/S Status]
Displays the HIM active device type.
Default:
N/A
Values
1 = Slave
2 = Master
Type:
Read Only
11
[HIM Ref Preset]
0 (Zero Start):
HIM Reference is always “0.0” at power on.
1 (Host Output): HIM will assume the Host’s output feedback
(bumpless transfer) and preset its Reference when
the Reference is configured to be received on the
RS-485 port. This can be verified by viewing
Diagnostics/Device Status/Remote Freq Ref = 1.
2 (Last HIM Ref): HIM will store the HIM Reference in EEPROM each
time it is changed. HIM Reference is restored at
power on.
Default:
0 = Zero Start
Values
0 = Zero Start
1 = Host Output
2 = Last HIM Ref
Type:
Read/Write