Rockwell Automation Publication 23P-IN007A-EN-P - June 2011

Step 6: Remove the
Bimetal Thermostat

1. Remove the stand-off and washer from the heatsink (if needed for additional

clearance).

2. Remove the bimetal thermostat from the heatsink and dispose of properly.

Step 7: Install the
New Bimental
Thermostat and
Reassemble the
SAR

1. Install the new bimetal thermostat in reverse order of removal. See

Remove the

Bimetal Thermostat on page 8

.

2. Install the field circuit board in reverse order of removal. See

Remove the Field

Circuit Board on page 6

.

3. Install the power interface circuit board and switching power supply circuit board in

reverse order of removal. See

Remove the Power Interface Circuit Board and

Switching Power Supply Circuit Board on page 5

.

4. Install the control circuit board in reverse order of removal. See

Remove the Control

Circuit Board on page 4

.

Stand-off

Bimetal Thermostat
Tightening Torque:
1.0 N•m (8.9 lb•in)

IMPORTANT

Thermal grease must be applied to the bottom of the bimetal thermostat
before securing it to the heatsink. Clean the surface of the heatsink and
the new bimetal thermostat with isopropyl alcohol, then apply a thin coat