Rockwell Automation 40BY1 Miniature End View Transmitted Beam Control User Manual
Installation instructions photoswitch
INSTALLATION INSTRUCTIONS
PHOTOSWITCH
MINIATURE END VIEW
TRANSMITTED BEAM CONTROL, BULLETIN 40BY1/47BU1- 4000
IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE. FOR ADDITIONAL INFORMATION REFER TO PUBLICATION PG-9000
BULLETIN NUMBER
TYPE
RESPONSE TIME
OPERATING DISTANCE
22DJ3--4000
22DJ4--4000
22DJ9--4000
22DJ9--4001
22DJ4--5000
22DJ9--5000
40BY1--4000
+
47BU1--4000
Light Source
Refer to
22 Series 4000
or
22 Series 5000
2 (.61m)
5 (1.52m)
3 (.90m)
Receiver
With 63--70 Range Extender
10 (3.05m)
25 (7.62m)
40BY1--4000
+
47BU1--4000
+
63--70
Diffuse
6 (.15m)
12 (.3m)
SPECIFICATIONS
Field of View
7.5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmitting LED
Infrared, 940nm
. . . . . . . . . . . . . . . . . . . . . . . .
Ambient Temperature Range
--40F to 185F (--40C to 85C)
. .
Approvals
UL Listed and CSA Certified
. . . . . . . . . . . . . . . . . . . .
Operating Environment
NEMA 3, 4, 12, 13 and IP66 (IEC529)
. .
Housing
High impact chemically resistant Housing
. . . . . . . . . . . .
Cable
Light Source
2 conductor vinyl jacketed cable 10 (3m)
. . . . . . .
Receiver
2 conductor vinyl jacketed cable 10 (3m)
. . . . . . . . . .
OPERATING DISTANCE SELECTION
The maximum operating distance is based on installing the control
in a relatively clean environment. Normal industrial environment ac-
tually ranges from moderately dusty to extremely dirty. Greater oper-
ating margin (excess gain) may be required, which can be obtained by
reducing the operating distance of the control. (optics should be
cleaned regularly.)
TYPICAL RESPONSE CURVE
10%
20%
30%
40% 50%
100%
Percent of Maxium Operating Range
T
2
T
1
Recommended Operating
Range Derating For “dirty”
Industrial Environments
Recommended Operating Range
Derating For “normal” Industrial
Environments
100X
50x
40x
30x
20x
10x
5x
4x
3x
2x
1x
Transmitted Beam Operating
Range Selection
OP
ERA
TIN
G
M
AR
GIN
INSTALLATION
The control must be securely mounted on a firm, stable surface or
support. A mounting which is subject to excessive vibration or shift-
ing may cause intermittent operation.
45
0
1/2R
(12.7)
.196 (5)
SLOT
13/64 (5.16)
DIA. HOLE
17/32
(38.9)
23/32
(18.3)
23/32
(18.3)
1 1/8
90
0
UNIVERSAL MOUNTING ASSEMBLY #61--4847