beautypg.com

Bosch VG4-200 User Manual

Page 54

background image

50

en | Troubleshooting Guide

AutoDome Modular Camera System

F01U064036 | 1.0 | 2007.01

VG4-200, VG4-300, VG4-500i Series User’s Manual

Bosch Security Systems, Inc.

No camera control

1.

Ensure that the keyboard and monitor are set to the correct (same) camera number.

If O.K., then:

2.

Check that the camera address is properly set. Enter ON-997-ENTER to display the cam-
era address.

If address is not set or is incorrect, then:
3.

Set the camera address using FastAddress (ON-998-ENTER).

If O.K., then:

4.

Check that the Amber LED on the AutoDome CPU turns on when receiving pan/tilt com-
mands from the controller keyboard. The Amber LED indicates control is being
received.

Amber LED on AutoDome CPU Module

Flash Sequence

Indicates:

Off

No incoming communications or no power

Solid for 2 seconds

Receiving good data

Fast blinking

Lost packet(s)

If amber LED does not light when given PTZ commands, then:
5.

Check if other cameras on the system can be controlled. If not, check the controller and
wiring connections.

If O.K., then:

6.

Check that the RS-232/485 selector switch is properly set to the proper protocol.

If O.K., then:

7.

Ensure that all Biphase, Bilinx, or RS-232/485 wires are properly connected. See the
AutoDome Modular Camera System Installation Manual.

If O.K., then:

8.

Check if you can access the AutoDome OSD menus (ON-46-ENTER).

If O.K., then:

9.

Confirm that the AutoDome passes homing (SET-110-ENTER).

If AutoDome fails homing, then:
10. Contact Bosch Technical Support.

Intermittent camera
control

1.

Check that only the last AutoDome in a daisy chain configuration is terminated with a
110

resistor across the +/- biphase terminals.

If O.K., then:
2.

Check that the maximum wire distance has not been exceeded for the control protocol
(the maximum distance for RS-232 is 50 feet). See the AutoDome Modular Camera Sys-
tem Installation Manual
.

If O.K., then:
3.

Check that all wiring meets Bosch recommended standards and specifications. See the
AutoDome Modular Camera System Installation Manual.

Camera moves when
moving other cam-
eras

1.

Check that the camera address is properly set (ON-997-ENTER). If the camera address
is not set, the AutoDome responds to control commands to any camera on the system.

If camera address is not set, then:
2.

Invoke the FastAddress Menu to assign a camera address (ON-998-ENTER).

Cannot access user
settings

X

Enter the unlock command OFF-90-ENTER. This command may require a password.
(Commands automatically lock in 30 minutes.)

This manual is related to the following products: