Rule # Choices:
Menu
Description
Sub-menu / Description
Default
Setting
Exit
Saves and exits the menu.
Enabled
Turns the rule on or off after its
inputs and outputs have been
defined.
YES to enable or NO to disable
NO
Input
Toggles through a list of valid
inputs set in the Alarm I/O Setup >
Inputs Setup Menu that define the
rule's inputs. A rule can have up to
four (4) inputs.
Alarm Inputs 1 – 7 and any additional
inputs which were set in the Inputs Setup
Menu, including Aux On/Off (1-99), Shot,
and NONE.
NONE
Output
Toggles through a list of valid out-
puts set in the Alarm I/O Setup >
Outputs Setup Menu that defines a
rule's outputs.
Alarm Outputs 1 – 3 and any additional
outputs set in the Outputs Setup Menu
including: Alarm Relay, Aux On/Off (1-99),
Shot, OSD, Transmit, and NONE.
Some outputs, such as Alarm Outputs 1-3,
Alarm Relay, and Aux On/Off can be set to
be active for a specific duration of time as
follows:
Seconds: 1-5, 10, 15, or 30
Minutes: 1-5 or 10
Latched: The alarm stays active until
acknowledged.
Follows: The alarm follows the alarm rule.
NONE
i
NOTICE! You can include up to four (4) Input and Output events in a single rule. Each input
and output, however, must be true for the alarm's rule to be valid and enabled.