2 camera setup menu – Bosch VG4-200 User Manual
Page 13
AutoDome Modular Camera System
On-Screen Display Menu Navigation | en
9
Bosch Security Systems, Inc.
VG4-200, VG4-300, VG4-500i Series User’s Manual
F01U064036 | 1.1 | 2007.01
2.2
Camera Setup Menu
The Camera Setup Menu provides access to camera settings that can be changed or custom-
ized. Menu items with an * are the default settings.
Camera Setup Menu Choices:
Camera Setup
Exit...
* White Bal:
EXT ATW
* Gain Control:
AUTO
* Max. Gain Level:
6
* Sharpness
6
* Synch Mode:
Internal
* Line Lock Delay:
0
* Backlight Comp:
OFF
* Shutter Mode:
Auto SensUP
* Shutter:
1/60
* Auto SensUP Max:
15x
* Night Mode:
AUTO
* Night Mode Color:
OFF
* Night Mode Threshold:
30
* Pre-Comp
1
Restore Defaults...
* = Factory Setting
Focus / Iris: Select
Menu
Description
Sub-menu / Description
Default Set-
ting
Exit
Exits the menu.
White Balance
Maintains proper color repro-
duction as the color tempera-
ture of a scene changes. For
example, from daylight to fluo-
rescent lighting.
Extended ATW: Adjusts camera color
using extended range.
ATW: Adjusts camera color constantly.
Indoor W.B.: Optimizes camera color for
typical indoor conditions.
Outdoor W.B.: Optimizes camera color
for typical outdoor conditions.
AWB Hold: Sets the camera's color set-
tings for the current scene.
Extended
ATW
Gain Control
Electronically brightens darker
scenes which may cause grain-
iness in low light scenes.
Auto or OFF
AUTO
Max. Gain Level
Adjusts the maximum gain
level that the gain control
adjusts to when set to AUTO.
Sliding scale: – (1 to 6) +
6
Sharpness
Adjusts the sharpness level of
the picture.
Sliding scale: – (1 to 16) +
6
Synch Mode
Sets the type of synchroniza-
tion mode for the camera.
INTERNAL: Synchronizes camera to an
internal crystal. This choice is recom-
mended if there is noise on the power
line.
LINE LOCK: Synchronizes camera to AC
power. This choice eliminates picture roll
in multi-camera systems.
INTERNAL
Line Lock Delay
Optimizes the LINE LOCK
mode to eliminate picture roll
in multiphase power applica-
tions.
Sliding scale: – (0º to 359º) +
0º