Installing the control – WarmlyYours PD Pro Snow Switch User Manual
Page 8

Snow Switch
®
Model PD Pro
Instruction Manual
23735
Rev. B
06/14 (800) 234-4239
http: www.networketi.com
Environmental Technology, Inc.
8 of 30
INSTALLING THE CONTROL
Install this unit in compliance with National Electrical Code (NEC) standards, as well as all other
local and applicable electrical codes for your area. Prior to beginning installation, make sure that
the facility has properly sized electric service and breaker. For additional information regarding
electrical ratings and facility power requirements, refer to the Specifications section of this
manual.
This unit is intended for wall mount installation only. The wall used for the installation should be
capable of supporting four times the weight of the unit, or about 20 pounds. Install the unit
directly to a solid, stable surface. The IP 66, NEMA 4X weather-resistant enclosure can be
installed either inside or outside.
Internal connections for any optional remote control unit or system sensor(s) will be made in the
next section.
The dimensions shown in the Top View of Figure 1 below are for the mounting hole location
footprint and run from centerline to centerline of the four slotted mounting holes. The dimension
shown in the Right Side View of Figure 1 is from the bottom of the enclosure to the top of the
clear plastic lid and shows the distance that the unit will protrude from the mounting surface.
Figure 1. PD Pro MOUNTING HOLE FOOTPRINT.
Top
View
Right Side View