APPENDIX K:

SLAB HEATING DIAGRAM: 240V - TYPICAL LINE DIAGRAM (FOR 6 CIRCUITS/CABLES) WITH THERMOSTAT CONTROL

240V CIRCUITS

LOW VOLTAGE (24V)

120V

CONTROL

POWER

Heater cable pigtail cold leads to be taken thru
3/4” (19mm) rigid metal conduit back to J-boxes.

Slab temp sensor probe to be enclosed
in metal conduit that is capped off,
between two passes of heat cable.

(conduit size as per installer)

240V CIRCUITS

240V
240V
240V

240V
240V
240V

J-BOX

J-BOX

HEATER CABLE

HEATER CABLE

HEATER CABLE

HEATER CABLE

HEATER CABLE

HEATER CABLE

TH115, 120V

THERMOSTAT

120/240 VAC

BREAKER PANEL

RLY-12P

RELAY PANEL

21