APPENDIX G:

SNOW MELT DIAGRAM 240V - TYPICAL LINE DIAGRAM (FOR 6 CIRCUITS/CABLES) WITH PREMIUM CONTROL

240V CIRCUITS

AIR-SS

LOW VOLTAGE (24V)

LOW VOLTAGE (24V)

120V

CONTROL

POWER

Heater cable pigtail cold leads to be taken through
3/4” (19mm) rigid metal conduit back to J-boxes.

Slab mounted temperature probe sensor
for high temp cut-off, to be housed inside
a 3/4” rigid metal conduit between two
passes of heater cable.

Aerial mounted snow sensor location
as per the installer.

Installer may use more J-boxes
outside or inside building.

(conduit size as per installer)

240V CIRCUITS

Outside

Inside

240V
240V
240V

240V
240V
240V

J-BOX

J-BOX

HEATER CABLE / MAT #1

HEATER CABLE / MAT #2

HEATER CABLE / MAT #3

HEATER CABLE / MAT #4

HEATER CABLE / MAT #5

HEATER CABLE / MAT #6

SCP-120

CONTROLLER

120/240 VAC

BREAKER PANEL

RLY-12P

RELAY PANEL

LOW

VOLTAGE

(24V)

REMOTE

CONTROL

OVERRIDE