Pfc micro mechanical drawings, Pfc micro, Pfc micro design guide – Vicor PFC Micro Power Factor Corrected AC-DC Switcher User Manual
Page 8

Pg. 8
Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474
03-000048 rev A
PFC Micro Design Guide
PFC Micro Mechanical Drawings
NOTES: UNLESS OTHERWISE SPECIFIED
2
32.69
1.29
190.50
7.500
31.04
1.22
MOUNTING HOLES; 2 PLACES
USE 8-32 X 0.25 or M4 X 6MM MAX LENGTH
FROM OUTSIDE OF UNIT
32.69
1.29
190.50
7.500
264.11
10.40
18.03
.71
88.90
3.500
6.35±0.51
.25±.02
4.09
.16
260.02
10.24
270.46±0.51
10.65±.02
MOUNTING HOLES; 4 PLACES
USE 8-32 X 0.12 or M4 X 3MM MAX LENGTH
FROM OUTSIDE OF UNIT
3
3
4
31.04
1.22
190.50
7.500
32.69
1.29
MOUNTING HOLES; 2 PLACES
USE 8-32 X 0.25 or M4 X 6MM MAX LENGTH
FROM OUTSIDE OF UNIT
4
3
2
PIN-1
4
1
L1
L2/N
GND
N/C
N/C
4
128.52
5.06
47.29
1.86
S1
S2
MBJ1 (5 PIN)
MBJ1 A/C INPUT
MATING CONNECTOR:
HOUSING: MOLEX (39-01-4051)
TERMINAL: MOLEX (39-00-0090)
CRIMP TOOL: MOLEX (11-01-0199)
CBJ3 INTERFACE CONNECTOR
MATING CONNECTOR:
HOUSING: MOLEX (50-57-9412)
SOCKET CRIMP 24-30 AWG: MOLEX (16-02-0097)
CRIMP TOOL: MOLEX (11-01-0209)
CBJ3 (12 PIN)
PIN REF
DESCRIPTION
CBJ3-1 SGND
SIGNAL
GROUND
CBJ3-2
PGR
POWER GOOD/READ
CBJ3-3
ACOK
AC POWER OK
CBJ3-4
ED6
ENABLE/DISABLE S2M3
CBJ3-5
ED5
ENABLE/DISABLE S2M2
CBJ3-6
ED4
ENABLE/DISABLE S2M1
CBJ3-7
ED3
ENABLE/DISABLE S1M3
CBJ3-8
ED2
ENABLE/DISABLE S1M2
CBJ3-9
ED1
ENABLE/DISABLE S1M1
CBJ3-10
GSD
GENERAL SHUTDOWN
CBJ3-11
PGDV
POWER GOOD/DATA VALID
CBJ3-12
Vcc
+5V@40mA
PFC MICRO
AIR
FLOW
WITH OPTIONAL BUS BAR
1
1
A COMPLETE SET OF MATING CONNECTORS
IS AVAILABLE FOR PURCHASE BY SPECIFYING
WESTCOR CONNECTOR KIT P/N: 19-130044.
1
2
REFERENCE DESIGNATIONS
MB
MOTHER
BOARD
CB
CONTROL
BOARD
S(x)
SLOT
NUMBER
M(x)
MODULE
NUMBER
DUAL OUTPUT UNIT
PICTURED (TWO
MAXI
MODULES)
QUAD OUTPUT
UNIT PICTURED
(FOUR MINI
MODULES)
-
+
-
+
10-32 STUDS
S1
S1
S2
S2
18 PIN CONNECTOR
S1/S2 J2 REMOTE SENS
ACCESS CONNECTOR
1
SEE PAGE 9 FOR DETAILED OUTPUT
CONNECTION INFORMATION .
16 PIN CONNECTOR
SIX OUTPUT UNIT
PICTURED (THREE
MICRO
MODULES)
1
1
1
1
NOTE: FOR INCREASED OUTPUT POWER, CURRENT SHARE BOARDS ARE
AVAILABLE.
WITH VI-200/VI-J00 MODULES
CSB-01
WITH MAXI/MINI/MICRO MODULES
CSB-02
(SEE PAGE 19 AND 20 FOR MORE INFORMATION ON CURRENT SHARE
BOARDS.
DIMENSIONS SHOWN ARE FROM BOTTOM SURFACE
MOUNTING PEMNUTS EXTEND .010 PAST BOTTOM
SURFACE.
All
W
est
cor po
w
e
r supplies can no
w be c
onfigur
ed online
using
V
SPOC,
the online c
onfigur
at
or t
o
ol a
v
ailable on vic
orpo
w
e
r.
co
m