Vicor Westcor PFC Mini Power Factor Corrected AC-DC Switcher User Manual
Page 22
UG:115
vicorpower.com
Applications Engineering: 800 927.9474
Page 22
Environmental (Cont.)
Shock and Vibration
(MI Chassis) Altitude
Mil-STD 810
Derate 2.6% total output power for each 1,000 ft to a maximum
operating altitude of 15,000 ft. Non-operating storage maximum
altitude is 40 K. 75% maximum load
Humidity
0 to 95% non condensing
Product Weight
5.5 lbs. (2,5 kg)
Dimensions
1.72" H (43,6 mm) x 6.0" W (152,4 mm) x 12.2" L (309,9 mm)
Warranty
[c]
2 years limited warranty.
See
[b]
45°C is the maximum operating temperature. If one is using a Maxi/Mini module less than 24 V output and
more
than 500 Watts, the maximum operating temperature is 40°C.
[c]
Opening, repairing or modifying the unit will void the warranty. If you have any problem with the power supply,
please contact Customer Service at 1-800-735-6200. If the unit needs to be returned for inspection/analysis, an
RMA number will be issued. All units must have a RMA number prior to return.
Ouput
VI-200/VI-J00 Modules
Parameter
MIN
TYP
MAX
UNITS
Notes
Setpoint Accuracy
[d]
Load/line Regulation
Load/line Regulation
0.5
1
± 0.2
± 0.5
%
%
%
of Vnom
10% to full load
No load to 10% load
Temperature Regulation
0.01
0.02
%/°C
Over rated temp.
Long Term Drift
Output Ripple & Noise:
≤10 Vout
>10 Vout
100
1.0
mV
% Vout
20 MHz bandwidth
20 MHz bandwidth
Voltage Trim Range
VI-200/VI-J00 series Slots
50-110
% Vout
± 10% on 10 – 15 Vout
Total Remote Sense
Compensation
0.5
Volts
Autosense.
See Pages 8 & 14
OVP Set Point
[e]
115
125
135
% Vout
Recycle Power
Current Limit
105
115
125
% of I max
Auto Recovery
Short Circuit Current
20 (105
[f]
)
130
%
Overtemperature Limiting
Not available on VI-J00
[d]
For special, adjustable voltages and 48 Vdc outputs, maximum setpoint accuracy is 2% of Vnom.
Note: See individual module data sheets for specific module specifications.
[e]
131% Nominal for Booster Modules. No OVP for VI-J00
[f]
VI-J00 modules only