Specifications 21, Specifications – Vicor Westcor PFC Mini Power Factor Corrected AC-DC Switcher User Manual
Page 21
UG:115
vicorpower.com
Applications Engineering: 800 927.9474
Page 21
General
Number of Outputs
1 – 6
Efficiency
>80%
Safety Approvals
cURus – UL 60950-1, CSA 60950-1;
cTÜVus – EN 60950-1, UL 60950-1, CSA 60950-1
CE Mark – Low Voltage Directive, 73/23/EEC amended by 93/68/EEC
Note: certain MI chassis may not carry all safety approvals
Maximum Output Power+
(+Not to exceed an input
current of 10 A)
>800 W at 115 Vac;
1,500 W at 230 Vac
Note: Only PFC Minis populated with 12 V Maxi modules are limited to 500 W max. per slot.
With 12 V Mini modules, it is limited to 250 W.
Input
Input
85 – 264 Vac, 47 – 500Hz; 100 – 380 Vdc
Line/Load Regulation
VI-200/VI-J00:± 0.2% max.10% to full load; ± 0.5% max.
0 to 10% load
Line Regulation
Maxi/Mini:± 0.20% max. to 0.3% max LL to HL, Full Load
Inrush Current
8.5A pk at 115 Vac; 17A pk at 230 Vac
Ride Through Time
20 ms at 1,200 W load
Conducted EMI
VI-200/VI-J00 Ss:
EN55022 Class B
Maxi, Mini
(some configs. may meet Class B):
EN55022 Class A
Mil-STD 461 will require external filter
Power Factor
0.99 at 115 Vac: 0.95 at 230 Vac
Voltage Fluctuations and Flicker
EN61000-3-3
ESD Susceptibility
EN61000-4-2, Level 3, Performance Criteria A
RF Radiated Immunity, 10v/m
EN61000-4-3, Performance Criteria A
Transient Burst Immunity
EN 61000-4-4, Level 3, Performance Criteria B
Surge Immunity
EN 61000-4-5 Installation Class 3, Performance Criteria B
RF Conducted Immunity
EN61000-4-6, Limit Class 3 Performance Criteria A
Voltage Dips and Interrupts
EN61000-4-11
Dielectric Withstand
Primary to Chassis GND = 2,121 Vdc
Primary to Secondary = 4,242 Vdc
Secondary to Chassis GND = 750 Vdc
MI Chassis Overvoltage and Transients
Compliant to Mil-STD 704 and 1399
Note: See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of
normal output voltage.
Environmental
Storage Temperature
-40°C to +85°C
Operating Temperature
Full Power
Half Power
-20°C to +45°C
[b]
(-40°C to +45°C optional with MI chassis)
-20°C to +65°C (-40°C to +65°C optional with MI chassis)
Specific temperature data on all module configurations can be obtained by contacting
Applications Engineering.
[b]
45°C is the maximum operating temperature. If one is using a Maxi/Mini module less than 24 V output and
more than 500 Watts, the maximum operating temperature is 40°C.
Specifications