General

Number of Outputs

1 – 6

Efficiency

>80%

Safety Approvals

cURus – UL 60950-1, CSA 60950-1;
cTÜVus – EN 60950-1, UL 60950-1, CSA 60950-1
CE Mark – Low Voltage Directive, 73/23/EEC amended by 93/68/EEC
Note: certain MI chassis may not carry all safety approvals

Maximum Output Power+
(+Not to exceed an input
current of 10 A)

>800 W at 115 Vac;
1,500 W at 230 Vac

Note: Only PFC Minis populated with 12 V Maxi modules are limited to 500 W max. per slot.
With 12 V Mini modules, it is limited to 250 W.

Input

Input

85 – 264 Vac, 47 – 500Hz; 100 – 380 Vdc

Line/Load Regulation

VI-200/VI-J00:± 0.2% max.10% to full load; ± 0.5% max.
0 to 10% load

Line Regulation

Maxi/Mini:± 0.20% max. to 0.3% max LL to HL, Full Load

Inrush Current

8.5A pk at 115 Vac; 17A pk at 230 Vac

Ride Through Time

20 ms at 1,200 W load

Conducted EMI

VI-200/VI-J00 Ss:

EN55022 Class B

Maxi, Mini

(some configs. may meet Class B):

EN55022 Class A

Mil-STD 461 will require external filter

Power Factor

0.99 at 115 Vac: 0.95 at 230 Vac

Voltage Fluctuations and Flicker

EN61000-3-3

ESD Susceptibility

EN61000-4-2, Level 3, Performance Criteria A

RF Radiated Immunity, 10v/m

EN61000-4-3, Performance Criteria A

Transient Burst Immunity

EN 61000-4-4, Level 3, Performance Criteria B

Surge Immunity

EN 61000-4-5 Installation Class 3, Performance Criteria B

RF Conducted Immunity

EN61000-4-6, Limit Class 3 Performance Criteria A

Voltage Dips and Interrupts

EN61000-4-11

Dielectric Withstand

Primary to Chassis GND = 2,121 Vdc
Primary to Secondary = 4,242 Vdc
Secondary to Chassis GND = 750 Vdc

MI Chassis Overvoltage and Transients

Compliant to Mil-STD 704 and 1399

Note: See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of
normal output voltage.

Environmental

Storage Temperature

-40°C to +85°C

Operating Temperature
Full Power
Half Power

-20°C to +45°C

[b]

(-40°C to +45°C optional with MI chassis)

-20°C to +65°C (-40°C to +65°C optional with MI chassis)

Specific temperature data on all module configurations can be obtained by contacting
Applications Engineering.

[b]

45°C is the maximum operating temperature. If one is using a Maxi/Mini module less than 24 V output and

more than 500 Watts, the maximum operating temperature is 40°C.