Standard Features
n
Power Factor Correction: 0.99 at 115 Vac; 0.95 at 230 Vac
n
Universal Input: 85 – 264 Vac, 47 – 500 Hz, or 100 – 380 Vdc
n
Power Output: 1,500 W at 230 Vac; 800 W at 115 Vac
n
Up to 6 isolated outputs (3 slots)
n
Fan cooled
n
Full power to 45°C; half power at 65°C
n
Conducted EMI:
VI-200/VI-J00 series:
Maxi, Mini, Micro series:
FCC Class B
FCC Class A
EN55022 Class B
EN55022 Class A
(certain configurations meet EN55022 Class B)
n
Harmonic Distortion complies with EN61000-3-2
n
AC Power OK status signal
n
Autosense (for more information, see Page 8 and Page 14)
n
Output overcurrent protection on all outputs
n
Output overvoltage protection (not applicable when using VI-J00)
n
Output overtemperature limiting (not applicable when using VI-J00)
n
Ride-through (hold-up) time: >20 ms at 1,200 W load (nominal line)
n
Size: 1.72" H (43,6 mm) x 6" W (152,4 mm) x 12.2" L (309,9 mm)
n
Safety Agency Approvals: CE Mark, cTÜVus, UL
(
Note:
Certain MI chassis may not carry all safety certs
)
Optional Features
n
Extended temperature range output converters
n
Current share board - see Page 24
n
RAM modules for low noise applications - see Page 27
n
Connector kit available (#19-130047)
n
Low leakage available - see Page 27
n
Office environment fan - see Page 27
n
MI chassis specific options
-
Mil-STD 810 for Shock and Vibration
-
Mil-STD 704 and 1399 for overvoltage and transients
-
-40°C Operation
-
Conformal coating - contact factory
Mechanical Considerations
The PFC Mini can be mounted on either of two surfaces using standard 8-32 (4 mm) size
screws. Maximum allowable torque is 4.4 in. lbs., and the maximum penetration is
0.16 in. (4 mm).