Standard Features

n

Power Factor Correction: 0.99 at 115 Vac; 0.95 at 230 Vac

n

Universal Input: 85 – 264 Vac, 47 – 500 Hz, or 100 – 380 Vdc

n

Power Output: 1,500 W at 230 Vac; 800 W at 115 Vac

n

Up to 6 isolated outputs (3 slots)

n

Fan cooled

n

Full power to 45°C; half power at 65°C

n

Conducted EMI:

VI-200/VI-J00 series:

Maxi, Mini, Micro series:

FCC Class B

FCC Class A

EN55022 Class B

EN55022 Class A

(certain configurations meet EN55022 Class B)

n

Harmonic Distortion complies with EN61000-3-2

n

AC Power OK status signal

n

Autosense (for more information, see Page 8 and Page 14)

n

Output overcurrent protection on all outputs

n

Output overvoltage protection (not applicable when using VI-J00)

n

Output overtemperature limiting (not applicable when using VI-J00)

n

Ride-through (hold-up) time: >20 ms at 1,200 W load (nominal line)

n

Size: 1.72" H (43,6 mm) x 6" W (152,4 mm) x 12.2" L (309,9 mm)

n

Safety Agency Approvals: CE Mark, cTÜVus, UL

(

Note:

Certain MI chassis may not carry all safety certs

)

Optional Features

n

Extended temperature range output converters

n

Current share board - see Page 24

n

RAM modules for low noise applications - see Page 27

n

Connector kit available (#19-130047)

n

Low leakage available - see Page 27

n

Office environment fan - see Page 27

n

MI chassis specific options

-

Mil-STD 810 for Shock and Vibration

-

Mil-STD 704 and 1399 for overvoltage and transients

-

-40°C Operation

-

Conformal coating - contact factory

Mechanical Considerations

The PFC Mini can be mounted on either of two surfaces using standard 8-32 (4 mm) size
screws. Maximum allowable torque is 4.4 in. lbs., and the maximum penetration is
0.16 in. (4 mm).