Unipac, Modupac – Vicor 4kW MegaPAC AC-DC Switchers User Manual
Page 9

UG:107
vicorpower.com
Applications Engineering: 800 927.9474
Page 9
ConverterPAC Output and Connector Pin Identification for the
3 Phase/4kW MegaPACs (Cont.)
POWER GOOD INVERTED
P2 REMOTE SENSE TRIM/SC & POWER GOOD
3
2
4
1
POWER GOOD
SIGNAL GROUND
Vcc IN
TERMINALS- MOLEX P/N: 39-00-0031
HOUSING- MOLEX P/N: 39-01-0073
MATING HDWR:
OUTPUT ADJUST
- VOUT
+ V0UT
P2-PIN1
7
6
5
+SENSE
-SENSE
TRIM
CRIMP TOOL MOLEX P/N: 57005-5000
UNIPAC
J2-PIN1
J3-PIN1
0UTPUT ADJUST
+ V0UT
- VOUT
(REMOTE SENSE)
J2
2
1
3
- SENSE
+ SENSE
MATING HDWR:
TRIM PIN ACCESS
3
POWER GOOD
2
1
SIGNAL GROUND
POWER GOOD INVERTED
MATING HDWR:
4
J3 DC OK (POWER GOOD)
Vcc IN
HOUSING- MOLEX P/N: 50-57-9403
TERMINALS- MOLEX P/N: 16-02-0103
CRIMP TOOL MOLEX P/N: 11-01-0208
HOUSING- MOLEX P/N: 39-01-0043
TERMINALS- MOLEX P/N: 30-00-0031
CRIMP TOOL MOLEX P/N: 57005-5000
MODUPAC
M-1 STATUS
M-1 VOLTAGE ADJUSTMENT
M-4 STATUS
M-3 STATUS
M-2 VOLTAGE ADJUSTMENT
M-2 STATUS
M-4 VOLTAGE ADJUSTMENT
M-3 VOLTAGE ADJUSTMENT
CONNECTOR
J1
MATING HDWR:
HOUSING MOLEX P/N 39-01-2120
TERMINALS MOLEX P/N 39-00-0039
CRIMP TOOL MOLEX P/N 11-01-0197
UniPAC
ModuPAC
JuniorPAC
RamPAC
FlexPAC
Note: The UniPAC can ONLY be used in the 4kW MegaPAC.