ConverterPAC Functional Description (Cont.)

FlexPAC
The FlexPAC output assembly consists of from 2 to 4 discrete outputs that convert the
high output bus to the desired output voltage. Each FlexPAC output can be manually
trimmed from 2V to 25V and supports up to 5 amps with a maximum output powerof
50W per output. All outputs maintain less than 50mV noise over the entire output
range. All outputs support local sense only. For electrical trim options and specific
output sequencing contact the factory

List of ConverterPACs used in the 3 Phase/4kW MegaPACs and their features

ConverterPAC

OVP

OCP

OTL

RS/AS*

LS/AS*

PG

TrimPot

ModuPAC

Std

Std

Std

AS*

AS*

Opt

Opt

JuniorPAC

N/A

Std

N/A

AS*

AS*

Opt

Opt

DualPAC

N/A

Std

N/A

AS*

AS*

N/A

Opt

RAMPAC

N/A

Std

N/A

AS*

AS*

Opt

Opt

BatPAC

N/A

Std

N/A

N/A

N/A

N/A

Std

UniPAC**

Std

Std

N/A

AS*

AS*

Opt

Opt

* See page 13 and 17 for more information on Autosense.
**

Currently, the UniPAC (XU) can only be used in the 4kW MegaPAC.

OVP

Overvoltage Protection (latching)

OCP

Overcurrent Protection (auto-recovery)

OTL

Overtemperature Limiting (latching)

RS

Remote Sense

PG

Power Good (DC OK TTL Signal)

LS

Local Sense

AS Autosense

Note: All ConverterPACs mentioned above can be paralleled EXCEPT the DualPAC,

JuniorPAC and RamPAC.

M-1 STATUS

M-1 VOLTAGE ADJUSTMENT

M-4 STATUS

M-3 STATUS

M-2 VOLTAGE ADJUSTMENT

M-2 STATUS

M-4 VOLTAGE ADJUSTMENT

M-3 VOLTAGE ADJUSTMENT

CONNECTOR

J1

FlexPAC