UG:107

vicorpower.com

Applications Engineering: 800 927.9474

Page 24

Setting the bottom limit:

V

R6

= 2.5 V - 10% = 2.25 V

And since I

R5

= I

R6

= 25 mA,

R6 = V

R6

/I

R6

= 2.25 V/25 mA = 90 kW

V

2

= V

1

+ V

R6

= 2.75 V + 2.25 V = 5 V

I

R7

= V

2

/R7 = 5 V/10 kW = 500 mA

I

R8

= I

R7

+ I

R6

= 525 mA

V

R8

= (V

nom

+10%) - V

2

= 13.2 V - 5 V = 8.2 V

Given: V

nom

= 12 V

R8 = V

R8

/I

R8

= 8.2 V/525 mA = 15.62 kΩ

Using the previous resistor combination, a 12 V output can be trimmed externally up
to 13.2 V and down to 10.8 V. For further information on external trimming, refer to
Chapter 5 of the Applications Manual or consult the factory for assistance.

CONSULT APPLICATIONS ENGINEERING WHEN TRIMMING OUTPUTS BELOW 5V.