MAINTENANCE

REMOVING VALVE

10) Remove the 8 Phillips head screws securing

the valve tray assembly in place (Diagram
6) and then lift the entire assembly out
(Diagram 7).

1) Shut off the gas and electrical supply.

2) Remove the louvers

3) Open

the

fl ush door and remove the door.

4) Remove the logs.

5) Remove the burner/grate assembly by
removing the 2 Phillips head screws.

Diagram 1: Remove the left and right screws.

Diagram 2: Slide burner assembly to the left

and then remove.

7) Remove the 2 screws securing the rear log

tray and lift out. Diagram 3

Orifi ce

9) Disconnect the wall switch wires from the

valve. (see Diagram 5)

Diagram 4

Diagram 3

Diagram 5

Diagram 6

Diagram 8

Diagram 7

INSTALLING VALVE

1) Place new valve tray into position

2) Reinstall the 8 hold down screws.

3) Hook up the 2 TP and 2 TH wires to the ap-

propriate connections on the valve.

4) Reinstall the rear log tray.

5) Install burner/grate assembly

6) Hook up the gas line and check for gas leaks

with a soap and water solution or a gas leak
detector. (Do not use open fl ame for leak
testing.)

7) Fire up the unit temporarily

8) Check the manifold pressure.

9) Reinstall the logs and brick panels as

needed.

10) Reinstall the door and replace the louvers.

11) Fire up the unit again and check for proper

fl ame appearance and glow on logs.

6) Slide the burner assembly to the left to release

it from the orifi ce, then lift it out.

8) Disconnect the inlet gas line.

(see Diagram 4)