Installation, Conversion to top vent – Regency Bellavista B36XT Medium Gas Fireplace User Manual
Page 16
16
Regency Bellavista™ B36XT Gas Fireplace
INSTALLATION
CONVERSION TO TOP VENT
Note: This conversion must be done prior to the unit being placed in position.
The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented.
Top Collar Assembly Kit
1
Intake Collar Assembly with Gasket
1
Intake Cover Plate with Gasket
1
Top/Rear Exhaust Assembly with Gasket
1
Heat Defl ector
1
Baffl e Plate
29
1/4" x 1/2" Screws (4 spares)
1
Restrictor
1
Intake Collar Gasket (spare)
1
Exhaust Assembly Gasket (spare)
1
Insulation Plate Cover
1
Insulation Filling
Exhaust Assembly
w/ gasket
Intake Cover Plate
w/gasket
Insulation cover
plate
Insulation fi lling
Intake Collar Assembly
Intake Collar Assembly
w/gasket
w/gasket
2) From inside the fi rebox, remove the top heat defl ector by removing
2 screws.
Heat Defl ector
Diagram 2
1) Remove the door assembly by releasing the adjustable latches and lifting up off the door frame assembly.
Adjustable Tension
Latch location
Diagram 1
Note: Components shown are installed on unit.
3) From inside the fi rebox, remove the baffl e plate by removing 4 screws
- remove top front screw fi rst. See Diagram 3.
Baffl e Plate
Diagram 3
4) From the inside of the fi rebox, remove the exhaust assembly by
removing the 8 screws. See Diagram 4.