Installation, Optional fan installation – Regency Bellavista B36XT Medium Gas Fireplace User Manual
Page 49
Regency Bellavista™ B36XT Gas Fireplace
49
INSTALLATION
OPTIONAL FAN INSTALLATION
Important: 120 Volt AC power is needed for the
fan switch and blower. The receptacle box will
be installed on the left hand side of the unit and
will need to be wired by a qualifi ed electrician
prior to fan assembly being installed. The neutral
(wider) slot of the polarized receptacle should
be at the top.
Unit must be grounded at all times. Do not
cut the ground terminal off under any
circumstances.
1) Shut the power off.
2) Open the bottom louver. Remove the
standard fl ush door.
3) A t t a c h t h e r e d a n d b l a c k w i r e s
to fan motor as shown in diagram 1.
4) Turn the fan base on its side (with the base
facing towards you) and then slide the fan
in towards the rear of the unit. Turn the fan
upright and slip it over the two mounting
studs. Take care not to damage the insulation
on the fan base. Ensure that the fan blades
do not rub against the valve tubing.
5) Connect fan ground cable to ground
l u g . R e f e r t o w i r i n g d i a g r a m .
Diagram 1
Black wire
Red wire
Diagram 2
Diagram 3
Diagram 4
Diagram 5
Clip
Diagram 6
TO REMOVE THE FAN
1) Shut the power off.
2) Reverse the above instructions.
Note: The bearings are lubricated for life.
Do not lubricate them. Make sure
you vacuum the fan area on a regular
basis.
IMPORTANT:
These fans collect a lot of dust from within
your home. Ensure you maintain these fan
motors on a regular basis by vacuuming
out the fan blades and housing using a soft
brush nozzle.
Push Fan down
on mounting pins
Electrical
Receptacle
Ground Lug
Plug fan power cord
i
l
8) Slide the the Fan control box
under the clip on the fl oor of the fi rebox.
(See Diagram 5)
9) Secure the fan wires and power cord by
attaching one of the adhesive backed wire
holder clips (Part #910-199) onto the unit
base. Use the second clip to bundle up the
wires approximately 4" from the control box.
6) Slide the thermodisc/cover assembly into
the bracket clip on the underside of the
fi rebox. Check that no wire will touch the
hot surfaces. Diagram 3 and 4.
7) Plug the fan power cord into the rear end of
the receptacle box to provide the maximum
clearance from the louvers.
*
Ensure that there is no interference with
the wires when the louver is closed and that
no wire will touch the hot metal surfaces or
sharp edges.