beautypg.com

Installation, Horizontal terminations, Hh1 v – Regency Bellavista B36XT Medium Gas Fireplace User Manual

Page 30: V1 h1 h v

background image

30

Regency Bellavista™ B36XT Gas Fireplace

INSTALLATION

HORIZONTAL TERMINATIONS

TWO (2) 90

O

ELBOWS (RIGID PIPE 4" X 6 - 5/8")

H

H1

V

Option V

H + H1

A)

0' Min. 2' Max.

B)

1' Min. 3' Max.

C)

2' Min. 4' Max.

D)

3' Min. 5' Max.

E)

4' Min. 6' Max.

F)

5' Min. 7' Max.

G)

6' Min. 8' Max

W i t h t h e s e o p t i o n s ,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90

o

elbows

is required.

One 90

o

elbow = Two 45

o

elbows.

Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994.

No Vent Restrictor Installed

HORIZONTAL TERMINATIONS

THREE (3) 90

O

ELBOWS (RIGID PIPE 4" X 6 - 5/8")

V1

H1

H

V

Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994.

Option V

H V + V1 H + H1

A)

0' Min. 1' Max. 1' Min. 2' Max.

B)

1' Min. 2' Max. 3' Min. 3' Max.

C)

2' Min. 2' Max. 5' Min. 4' Max.

D)

3' Min. 2' Max. 7' Min. 5' Max.

E)

4' Min. 3 Max. 9' Min. 6' Max.

F)

5' Min. 4' Max. 10' Min. 7' Max.

G)

6' Min. 5' Max. 11' Min. 8' Max.

H)

7' Min. 6' Max. 12' Min. 9' Max.

With these options,
max. total pipe length
is 30 feet with min. of
12 feet total vertical
and max. 9 feet total
horizontal.

Please note min. 1
foot between 90

o

elbows is required.

One 90

o

elbow = Two 45

o

elbows.

No Vent Restrictor Installed