INSTALLATION

MANTEL CLEARANCES

Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.

Due to the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
the diagram on the right.

Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.

Mantel Clearances
B36XT

A

B

C

D

From Top of Fireplace
Opening

32"

(813mm)

21"

(533mm)

17-1/2""

(445mm)

13"

(330mm)

Combustible

Mantel Clearances

2

0

12

6

4

8

10

0

Top of

Fireplace

Opening

12”

1"

7”

A

B

C

Non-combustible

Header

(steel stud)

on edge

14

To Floor

Inches

D

Side View

7”

Non-combustible

Standoff