Installation, Lp tank installation - pto30cft only, Warning – Regency Plateau PTO30IST Outdoor Gas Firetable User Manual
Page 18
18
Regency Plateau
®
Series Outdoor Gas Fireplace
INSTALLATION
LP TANK INSTALLATION - PTO30CFT ONLY
Gas connection
@ tank
NOTE: Max. tank size 11lb.
1) Remove end panel (opposite end of switch panel),.
2) Remove long side panel (left panel if facing ON/OFF switch end), to ac-
cess the 3/8" fi tting to the gas control.
3) Loosen butterfl y bolt to allow LP tank to be seated on the holder.
4) Seat tank on tray and tighten butterfl y bolt to secure tank to tray.
5) Connect the LP regulator quick connect to the tank.
7) Check all gas connections (both valve train & LP tank) under normal
operating pressure, for leaks, with soapy water.
NOTE: If soap bubbles, this would indicate a gas leak.
919-031
WARNING!
When using a LP tank - a minimum 1”(25mm) gap
at all times, between the floor and base of unit.
(Refer to owners manual)
must be maintained
IMPORTANT:
PTO30 CFT (Coffee table only)
To avoid tank pressure regulator freezing - when using an 11LB LP tank,
it is recommended the appliance is run on low (turned down 30%).