beautypg.com

Installation, Lp tank installation - pto30cft only, Warning – Regency Plateau PTO30IST Outdoor Gas Firetable User Manual

Page 18

background image

18

Regency Plateau

®

Series Outdoor Gas Fireplace

INSTALLATION

LP TANK INSTALLATION - PTO30CFT ONLY

Gas connection

@ tank

NOTE: Max. tank size 11lb.

1) Remove end panel (opposite end of switch panel),.

2) Remove long side panel (left panel if facing ON/OFF switch end), to ac-

cess the 3/8" fi tting to the gas control.

3) Loosen butterfl y bolt to allow LP tank to be seated on the holder.

4) Seat tank on tray and tighten butterfl y bolt to secure tank to tray.

5) Connect the LP regulator quick connect to the tank.

7) Check all gas connections (both valve train & LP tank) under normal

operating pressure, for leaks, with soapy water.

NOTE: If soap bubbles, this would indicate a gas leak.

919-031

WARNING!

When using a LP tank - a minimum 1”(25mm) gap

at all times, between the floor and base of unit.

(Refer to owners manual)

must be maintained

IMPORTANT:

PTO30 CFT (Coffee table only)
To avoid tank pressure regulator freezing - when using an 11LB LP tank,
it is recommended the appliance is run on low (turned down 30%).