Installation – Regency Plateau PTO30IST Outdoor Gas Firetable User Manual
Page 17
![background image](/manuals/573835/17/background.png)
Regency Plateau
®
Series Outdoor Gas Fireplace
17
INSTALLATION
10) Remove two screws to remove valve cover panel.
12) Attach the label “This unit has been converted to LPG” near or on top of
the serial # decal.
13) Replace yellow “NG” label with red “LPG” label.
11) Remove Hi/Lo pressure regulator by removing 2 screws as shown below.
Reverse steps to install LP pressure regulator.
HI/LO pressure
regulator
9) Remove end panel (panel w/ switch) from unit.
Gas connection
@ unit
14) Remove NG gas line, if installed - replace with LP regulator and quick
connection.
15) Check all gas connections (both valve train & LP tank) under normal
operating pressure, for leaks, with soapy water.
NOTE: If soap bubbles, this would indicate a gas leak.
16) Install LP tank (see LP tank installation in this manual).
17) Check inlet and outlet pressures.
18) Check operation of fl ame control.